Model NO.: 2X-70A
Item: Oilless Rotary Vane Vacuum Pump
Pumping Speed(L/S): 70
Ultimate Pressure(PA): ≤6*10-2
Rotary Speed(R/Min): 420
Motor Power(Kw): 5.5
Noise(Dba): ≤86
Inlet Diameter(Mm): 80
Oil Capacity(L): 4.2
Weight(Kg): 320
Trademark: NANBEI
Specification: ISO
Origin: Henan, China
HS Code: 8414100040
Model NO.: 2X-70A
Item: Oilless Rotary Vane Vacuum Pump
Pumping Speed(L/S): 70
Ultimate Pressure(PA): ≤6*10-2
Rotary Speed(R/Min): 420
Motor Power(Kw): 5.5
Noise(Dba): ≤86
Inlet Diameter(Mm): 80
Oil Capacity(L): 4.2
Weight(Kg): 320
Trademark: NANBEI
Specification: ISO
Origin: Henan, China
HS Code: 8414100040
Product Introduction
This series of pumps are elementary equipment for pumping air from sealed vessels. It can be used alone, also can be used as the forepump, process pump or titanium pump of booster pump, roots vacuum pump, gas circulation cooling roots pump, oil diffusion pump, and molecular pump.It is applicable to vacuum coating, vacuum heat treatment, vacuum smelting, vacuum tube, bulb, refrigeration, chemicals, packing, forming, health and medical appliances, laboratory, vacuum drying machines and vacuum filtering.
Features:
 a. The pump can work continuously in the temperature between 5 to 40 centigrades and inlet pressure less than 1330Pa.
 b. Equipped with gas ballast valve to pump a little water vapor. It can last service life of  the  oil except the 2X-4A type.
c. Dedicated vacuum pump for making neon lights.
d. Many suction holes in the vacuum pump to save electricity.
Technical parameters:
Model |
2X-4A |
2X-8A |
2X-15A |
2X-30A |
2X-70A |
2X-100A |
|
Pumping speed(L/s) |
4 |
8 |
15 |
30 |
70 |
100 |
|
Ultimate pressure(Pa) |
≤6*10-2 |
≤6*10-2 |
≤6*10-2 |
≤6*10-2 |
≤6*10-2 |
≤6*10-2 |
a |
Motor power(Kw) |
0.55 |
1.1 |
2.2 |
3 |
5.5 |
7.5 |
|
Temprature |
                      ≤40ºC |
|
Noise(dBA) |
≤75 |
≤78 |
≤80 |
≤82 |
≤86 |
≤90 |
|
Inlet diameter(mm) |
25 |
40 |
40 |
65 |
80 |
90 |
|
Oil capacity(L) |
1 |
1.5 |
2 |
3 |
4.2 |
5 |
|
Electro-vacuum differential pressure valve |
DYC-Q25 |
DYC-Q40 |
DYC-Q40 |
DYC-Q65 |
DYC-Q80 |
DYC-Q100 |
|
Cooling speed(L/mm) |
   - |
       -       |
    -    |
71 |
72 |
72 |
c |
Notes:
Use seater mercury vacuum gauge to test in the inlet port of pump
b. Use thermocouple gauge, resistance gauge or some other total pressure type gauge to testÂ
c. The diameter of inlet port and outlet port is G3/8"
Product Introduction
This series of pumps are elementary equipment for pumping air from sealed vessels. It can be used alone, also can be used as the forepump, process pump or titanium pump of booster pump, roots vacuum pump, gas circulation cooling roots pump, oil diffusion pump, and molecular pump.It is applicable to vacuum coating, vacuum heat treatment, vacuum smelting, vacuum tube, bulb, refrigeration, chemicals, packing, forming, health and medical appliances, laboratory, vacuum drying machines and vacuum filtering.
Features:
 a. The pump can work continuously in the temperature between 5 to 40 centigrades and inlet pressure less than 1330Pa.
 b. Equipped with gas ballast valve to pump a little water vapor. It can last service life of  the  oil except the 2X-4A type.
c. Dedicated vacuum pump for making neon lights.
d. Many suction holes in the vacuum pump to save electricity.
Technical parameters:
Model |
2X-4A |
2X-8A |
2X-15A |
2X-30A |
2X-70A |
2X-100A |
|
Pumping speed(L/s) |
4 |
8 |
15 |
30 |
70 |
100 |
|
Ultimate pressure(Pa) |
≤6*10-2 |
≤6*10-2 |
≤6*10-2 |
≤6*10-2 |
≤6*10-2 |
≤6*10-2 |
a |
Motor power(Kw) |
0.55 |
1.1 |
2.2 |
3 |
5.5 |
7.5 |
|
Temprature |
                      ≤40ºC |
|
Noise(dBA) |
≤75 |
≤78 |
≤80 |
≤82 |
≤86 |
≤90 |
|
Inlet diameter(mm) |
25 |
40 |
40 |
65 |
80 |
90 |
|
Oil capacity(L) |
1 |
1.5 |
2 |
3 |
4.2 |
5 |
|
Electro-vacuum differential pressure valve |
DYC-Q25 |
DYC-Q40 |
DYC-Q40 |
DYC-Q65 |
DYC-Q80 |
DYC-Q100 |
|
Cooling speed(L/mm) |
   - |
       -       |
    -    |
71 |
72 |
72 |
c |
Notes:
Use seater mercury vacuum gauge to test in the inlet port of pump
b. Use thermocouple gauge, resistance gauge or some other total pressure type gauge to testÂ
c. The diameter of inlet port and outlet port is G3/8"
Plastic Injection Molded Connector Accessories
Mechanical properties of injection connector fittings as far as connection functions are concerned, insertion and extraction forces are important mechanical properties. Plug force is divided into insert force and pull out force (pull out force is also called separation force), the requirement of both is different. In the relevant standards, there are provisions for maximum insertion force and minimum separation force, which indicate that, from the point of view of use, the insertion force should be small (hence the structure of LIF with low insertion force and ZIF without insertion force), and if the separation force is too small, it will affect the reliability of contact.
Another important mechanical property is the mechanical life of the connector. Mechanical life is actually a kind of durability index, which is called mechanical operation in GB5095. It is based on a cycle of one insert and one pull, and whether the connector can normally complete its connection function (such as contact resistance) after the specified plug cycle. The plug force and mechanical life of the connector are related to the plating quality (sliding friction coefficient) of the contact part of the contactor structure (positive pressure size) and the dimensional accuracy (alignment) of the contactor.
Plastic Injection Molded Connector Accessories,Injection Molded Connector Accessories,Furniture Connector Bolts,Joint Connector Nuts,Joint Connector
Timeplex Industrial Limited , https://www.catimeplexhk.com