Industry Mold Temperature Regulator for Extrusion Industry Â
 BRIEF DESCRIPTION
WWW.MAIPT.LTD/
Â
Mold Temperature Control Units(TCU) PID process controller are used to preheat a process to the desired operating temperature by engaging the unit's electric immersion heater and recirculating the oil in the system. Water type TCU circulate high temperature heat transfer fluid through the process application for temperature control.
MPR series TCU is pecially engineered for the temperature control of Rubber & Plastic industry. This series are highly customizable, has special forced cooling function with high-strength cooling capacity.
MPR series TCU offer the temperature range from 15°C to 98 °C, customized heating capacity and voltages are available.
 FEATURES / FUNCTIONS / SAFETY PROTECTIONS
WWW.MAIPT.LTD/
Â
 BASIC FUNCTIONS
* OPTIONAL FUNCTIONS
- Thermometer for return water
Â
* Control mode: PLC
- Switchover of heating power
Â
* Explosion-proof device
- Automatic air-exhausting after startup
Â
* RS485 remote control function
- Control mode: Microcomputer control
Â
* Air-blowing and return water function
- BY-PASS pressure release loop for hot water
Â
* Customizable multi-point Temperature unit
- SUS integrated pipelines for less pipe resistance
Â
* Customizable horse power and heating power for water pump
- System pressure & Functional test before shipping
Â
Â
 SAFETY PROTECTIONS                                                  Â
 Temperature anomaly                                  Â
→
 Alarm and cut off power, when cycle-water's Temp. exceed upper limit.
 Power reverse                                            Â
→
 Power supply phase detection to prevent pump reverse, alarm indication.
 Pump overload
→
 Thermal overload relay protect pump from overloading, alarm indication.
 Low water protection
→
 Level-switch detects the oil level, prevent low water and alarm indication.
 Pressure anomaly
→
 Automatic stop heating operation when system pressure anomaly.
 Anomaly heating
→
 Heating contactor working, and anomaly heating alarm indication.